Máy dò ngọn lửa

Honeywell Analytics

FS20X Flame Detector

Detects hydrocarbon and non-hydrocarbon fires in all conditions

Electronic Frequency Analysis™, WideBand IR™ Technology

CERTIFICATIONS: INMETRO, CU-TR, SIL Rating, EN54-10, china-EX

Material: Aluminum, Stainless Steel

The Fire Sentry FS20X is a multi-spectrum (UV/Dual IR/VIS) fire and flame detector. The Fire Sentry FS20X detector represents a leap forward in integrating Infrared and Ultraviolet sensing technology, demonstrating faster false alarm-free response to fires in a range of temperatures. wider range and with a much longer detection range than conventional UV/IR detectors.

The Fire Sentry FS20X detector uses advanced patented algorithms for signal processing and flame and flame analysis designed to alarm all types of fires in all public environmental conditions.

Specifications :

Field of view: 90° horizontal cone to line of sight, 45° to axis Highest sensitivity: (45m to 60m), mid-range (30m) and lowest (15m) – depending on conversion needs

Response time:

  • 3-5 Seconds to 0.1 m2 (1 sq. ft.) n-Heptane fire at 30 m (100 ft.) 3-10 Seconds to 0.1 m2 (1 sq. ft.) n-Heptane fire at 60 m (200 ft.)
  • SPECTRAL SENSITIVITY Ultraviolet: 185 - 260 nanometres Visible: 400 - 700 nanometres Near Band IR: 0.7 - 1.1 microns Wide Band IR: 1.1 - 3.5 microns
  • Real-time clock with data logging up to 200 events with historical date and time data
  • Power required :24 Vdc .
  • Output relay:  Alarm, Fault and Fire
  • Dual processors, one sample and signal processor, freeing the other for data FirePic storage Store
  • Up to 6 pre-fire event data 
  • Resistance to RFI and EMI
  • Protection standard: IP66
  • Approvals: FM, cFM, ATEX, IECEx, En54-10 and SIL 2
  • Power Consumption: 85 mA @ 24 Vdc
  • ANALOG OUTPUT 0 - 20 mA, user-selectable
  • LOOP RESISTANCE 50 - 400 Ohms
  • Optional communication: • RS-485, ModBus Protocol • RS-485, FireBus II • RS-485 Special (optional) • HART, Optional plug-in module (not available on EN54-10 units)
  • Display light: Green light - good use, Yellow light - error, Red light - broken device (need repair and replacement)
  • Operating Environment: -40 to +85ºC   (-40 to +185ºF)         
  • Storage: -55 to +110ºC (-67 to +230ºF)
  • Humidity : 5 to 98% RH non-condensing
  • Standard requirements: Two M25 or two ” NPT
  • Materials: Powder-coated aluminum without copper, 316 . stainless steel